Mass trapping is a measurable, insecticide-free approach to mosquito population suppression. By deploying high-efficacy, odor-baited traps at scale, host-seeking mosquitoes are continuously removed from the environment. Unlike area-wide chemical control, mass trapping is selective, scalable, and data-driven, with each trap providing quantitative performance metrics.
The approach addresses key challenges in modern mosquito control, including insecticide resistance, environmental sensitivity, and public acceptance. It is particularly suited for research trials, pilot programs, and operational deployments in settings where chemical interventions are limited or undesirable, and where demonstrated efficacy is required.
Mass trapping is not a single product but a system. Effective programs combine our high-performance traps, human-odor attractants, and (optionally) CO₂, strategic placement and density, consistent servicing, and ongoing monitoring. When properly implemented, removal rates exceed population replacement, leading to reduced biting pressure and sustained population suppression.

Mosquito Monitoring and Surveillance
Reliable mosquito monitoring is essential for understanding mosquito populations, tracking invasive species, and assessing potential public health risks. Biogents monitoring traps are based on extensive research into mosquito host-seeking behaviour and are designed to provide reliable sampling data for scientific research, surveillance programs, and vector control operations.
Different monitoring applications require different trapping approaches. Depending on the target species, life stage, and research objectives, Biogents offers specialized solutions for monitoring host-seeking mosquitoes, gravid Aedes females, and a broader range of mosquito species. This includes the BG-Sentinel, BG-Pro, and BG-GAT, which can be adapted to different field conditions and sampling requirements.
Standardized monitoring helps researchers assess seasonal activity, compare mosquito populations across locations, identify changes in species composition, and evaluate the effectiveness of control interventions. With automated monitoring solutions such as the BG-Counter, mosquito surveillance can also be extended through continuous data collection and remote monitoring.
By combining scientifically developed trapping systems with appropriate sampling strategies, Biogents supports researchers and public health professionals in generating meaningful data for evidence-based mosquito surveillance and control.
A. Choosing the Right Trap
The following selection guide is a starting point; the target species, study protocol, local conditions, and accessory availability determine the final setup.
| Research objective | Starting point | Considerations |
|---|---|---|
| Host-seeking Aedes surveillance | BG-Pro or BG-Sentinel | Select the attractant and ground placement for the target species. Use the BG-Pro without UV light strip. |
| Broad adult mosquito surveillance | BG-Pro or BG-Sentinel with CO₂ | Standardize CO₂ delivery and sampling conditions. |
| Gravid Aedes surveillance | BG-GAT Reflect-Tech | Water and oviposition cues; samples a different behavioral group. It is much more specific for Aedes than suction traps. |
| Flexible trap use | BG-Pro | Document if you used EVS-, CDC-, or Sentinel-style configuration. |
| Continuous monitoring or mass trapping at fixed sites | BG-Protector 12V | Standalone configuration; control outcomes depend on deployment and study design. |
| Automated remote monitoring | BG-Counter 2 with BG-Protector 12V | CO₂, 12 V, cellular coverage and subscription needed; validate locally. |
| Biting midges, sandflies, black flies | BG-Pro with collection set for biting midges | Check the recommended UV and CO₂ setup. Biogents traps are not optimized for sampling these species. We recommend first identifying the ideal BG-Pro configuration for your specific use case. |
Which Biogents trap is best suited to my research project?
The most suitable Biogents trap depends on your target mosquito species, research objective, and sampling requirements.
- BG-Pro: A modular active suction trap that can be configured in EVS-style, CDC-style, or BG-Sentinel-style setups. It is suitable for a broad range of mosquito monitoring applications and can be combined with attractants, CO₂ and optional UV light. The BG-Pro can also run on a 10,000 mAh USB power bank for about one to two days, which is especially convenient for monitoring in remote locations. Its compact, lightweight design makes it easy to transport to remote monitoring sites.
- BG-Protector 12V: A robust suction trap for continuous outdoor monitoring and mass trapping at fixed sites. It can also serve as a base for the BG-Counter.
- BG-Sentinel: An established active suction trap particularly suitable for monitoring anthropophilic Aedes species, including Aedes aegypti and Aedes albopictus. Adding CO₂ broadens its application to general mosquito surveillance.
- BG-GAT Reflect-Tech: A passive trap designed to attract gravid female Aedes mosquitoes seeking an oviposition site. The sticky cards need to be replaced every one to two weeks. The trap is highly sensitive and specific for container-breeding Aedes mosquitoes. However, its catch rate is much lower than that of a Biogents suction trap.
- BG-Counter 2: An automated monitoring device that counts mosquitoes entering a Biogents suction trap and transmits the data to a cloud-based application.
Before selecting a trap, define whether you want to collect host-seeking or gravid females, whether you need broad-spectrum mosquito surveillance, how frequently samples must be collected and whether specimens need to be preserved for further laboratory analysis.
For complex research projects, Biogents can also help identify suitable configurations and accessories; contact us at research-webshop@biogents.com.
Which Biogents trap is the best starting point for most field studies? For most mobile field studies, we recommend the BG-Pro. Its modular design can be configured in Sentinel-, CDC-, or EVS-style, used standing or hanging, and powered from several sources. It is compact, easy to transport, and designed for mosquito surveillance and research. The final configuration should still be selected for the target species, habitat, sampling period, and available CO₂ and power supply.
What is the difference between host-seeking and gravid mosquito monitoring?
Host-seeking and gravid mosquito monitoring target different physiological and behavioral stages of female mosquitoes.
Host-seeking females are actively searching for a blood meal. Active suction traps such as the BG-Pro, BG-Sentinel and BG-Protector use a combination of visual, olfactory and airflow-related cues to attract and collect approaching mosquitoes.
Gravid females have already taken a blood meal and are searching for a suitable site to lay their eggs. The BG-GAT imitates an oviposition site and attracts gravid container-breeding Aedes females through visual and water-related cues.
Because these traps target different behavioral groups, their catch data should be analyzed separately. Combining both trap types can provide a more comprehensive picture of local container-breeding Aedes populations.
What is the difference between the BG-Pro and the BG-Sentinel?
Both the BG-Pro and the BG-Sentinel are active suction traps designed for professional mosquito monitoring.
The BG-Sentinel is a widely established monitoring trap, particularly for anthropophilic Aedes species. It is collapsible, lightweight, and designed to imitate the airflow and scent distribution associated with a human host.
The BG-Pro is a newer modular system that combines several commonly used trap configurations in one product. It can be assembled in EVS-style, CDC-style, or BG-Sentinel-style configurations.
The BG-Pro also offers lower power consumption and can be operated with 5 V or 6 V power sources, including compatible USB power banks.
In a direct comparative study, the BG-Pro achieved equivalent or higher collection performance than the BG-Sentinel, BG-Mosquitaire, CDC miniature light trap, and EVS trap under the tested conditions.
For new monitoring projects requiring flexibility, the BG-Pro offers several operational advantages. The BG-Sentinel remains relevant for existing surveillance programs and studies that require continuity with established methods.
Can catch numbers from different mosquito traps be compared directly?
Not without considering differences in trap design, attractants, sampling duration, and operating conditions.
Different trap models may have substantially different capture efficiencies depending on the target species and environmental conditions.
For meaningful comparisons, document and standardize at least the following parameters:
- Trap model and configuration
- Attractant type and replacement interval
- CO₂ source ,application time, and release rate
- Sampling duration
- Trap height and placement
- Habitat and surrounding vegetation
- Weather conditions
- Collection method and species identification procedure
If different trap models are compared within the same study, randomized and replicated designs such as Latin square experiments can help account for spatial and temporal variation.
Raw catch numbers should always be interpreted in relation to the specific sampling method.
How should I design a comparative mosquito trapping study?
A robust comparative trapping study should control for as many environmental and operational variables as possible.
We recommend considering the following aspects:
- Define your target species and research objective. Decide whether you want to compare overall mosquito abundance, species-specific catch rates, physiological stages or detection probability.
- Select suitable trap models and configurations. Ensure that the selected setups are appropriate for the target species.
- Standardize attractants and CO₂. Use consistent lure types, replacement intervals and CO₂ release rates. For CO₂ release rates, do not rely on the setting of the pressure regulator. To standardize CO₂ flow, you must use a flow meter (not available from Biogents).
- Randomize trap positions. Avoid systematic placement bias.
- Use sufficient replication. Multiple trapping locations and repeated sampling periods improve the robustness of your results.
- Document environmental conditions. Record temperature, humidity, vegetation, rainfall, and other relevant site characteristics.
- Standardize specimen handling. Apply consistent collection, storage and identification procedures.
For comparative field trials, Latin square designs can be useful because trap positions are rotated over successive sampling periods.
The BG-Pro evaluation by Degener et al. (2021), for example, used one semi-field experiment and nine field Latin square trials across seven countries.
Where should I position my mosquito traps?
Trap placement can have a substantial influence on mosquito catch rates.
For active suction traps, consider the local mosquito ecology and target species. Biogents generally recommends testing different locations and selecting suitable sites that provide favorable mosquito activity conditions.
For BG-Sentinel applications, shady, wind-protected and relatively moist locations near mosquito habitats are recommended.
The BG-GAT should be positioned where its black body is visible to approaching mosquitoes but protected from direct rainfall. Bushes are a good location, but make sure the vegetation is not too dense.
For comparative studies, use consistent placement criteria and document the exact trap positions and distance between traps throughout the study.
Can Biogents traps be used for both monitoring and population control?
Yes. Biogents traps can be used for both mosquito monitoring and control, but the setup depends on the objective, target species, and local conditions.
For monitoring, traps are placed at selected locations to track mosquito activity and identify the species present. A BG-Counter can be added to selected suction traps to provide automated data on activity over time. BG-GATs can complement suction traps by targeting gravid, container-breeding Aedes females.
For control, traps are deployed at a higher density to remove mosquitoes and reduce nuisance. For example, suction traps such as the BG-Protector with CO₂ can be combined with BG-GATs, which target a different part of the mosquito population. A BG-Counter is not needed on every suction trap; selected Counters can be used to monitor activity.
Monitoring and mosquito control have different objectives. While individual traps can already provide valuable data for monitoring, effective mosquito control generally requires a higher trap density and a deployment strategy adapted to local conditions.
How far should the trap be from people?
As a practical starting point, place the trap about five to 10 meters away from areas where people sit or work. The goal is to intercept mosquitoes at resting or approach zones rather than place the trap directly beside a competing human host. Local wind, vegetation, breeding sites, and the target species can justify a different distance, so verify performance in the field
How far apart should multiple traps be?
For monitoring, a starting point is approximately 100–200 m between traps. For mass trapping, a starting point is approximately 10 traps per hectare. The appropriate spacing or density depends on the study objective, terrain, wind, and target species. Define it in the study protocol and keep it consistent.